Fabric Testing

The industry’s only fabric protecting against the three major hazards: Flash Fire, Electrical Arc Flash and Molten Metal, not only does Spentex® HP 6 oz. Fabric provide industry-leading protection, but it also yields unsurpassed breathability and comfort.  Unlike FR-treated fabrics that lose their FR protection over time, Spentex® is inherently flame resistant, with FR protection built right into the fiber.

Test/Standard/CertificationResultsRequirement
NFPA 2112
Flash fire compliance standard

CompliantCompliant
NFPA 70E
Electrical safety standard - industrial electrical maintenance workers

Compliant - HRC 2 as single layerCompliant
ASTM D1909
Moisture regain (measure of comfort for wearer)

7.7815% better than FR cotton

Test/Standard/CertificationResultsRequirement
ASTM-4108-87
TPP Factor (cal/cm2 sec) Measures amount of heat transfer through fabric
13.2Compliant
ASTM D6413-87
After flame time (seconds)
Vertical 0
Horizontal 0
2 second maximum
2 second maximum
ASTM D6413-87
Char length (mm)
Vertical 6
Horizontal 7
150 mm maximum
150 mm maximum
ASTM 1930
Evaluation of flame resistant clothing for protection against flash fire simulations using an instrumented manikin (3 second exposure)
Compliant50% maximum for 2nd and 3rd degree burns
NESC 2007, Rule 410A3
Details app. Protection levels based on hazard for FRC selection
CompliantCompliant
ASTM 1506
Flame resistance fabric properties - momentary electrical arc hazards
CompliantCompliant
ASTM F2302
Minimum requirements for labeling garments as flame and heat resistant
CompliantCompliant
ASTM F1959-05
Arc Thermal Performance Value (ATPV) (cal/cm2)
9.2Hazard Risk Category 2
ASTM F1959-07
Arc rating (afterflame, seconds)
0No Afterflame
ASTM F1959-08
Arc rating (break open)
No break openNo break open
NFPA 1975
Measures FR properties/durability/colorfastness/steam strength of fabric through 100 wash cycles
CompliantCompliant
ASTM D2863
Limiting Oxygen Index (LOI)
>41.020.95
ASTM D1424
Elmendorf Tear Strength, lbs.
CompliantExceeds MIL-C 83429B Type II
ASTM F955
Test method for molten splash
Tested for molten zinc, steel and aluminumNo burn through or shrinkage

Button | Got a Question ?
Button | How Can We Help You?
Video | Spentex® Demos

Product Demos

Spentex® v. NOMEX® v. FR Cotton Fabric Heat Stress

Spentex® v. NOMEX® v. FR Cotton
Heat Stress Test


Spentex® v. NOMEX® Flash Fire Demonstration

Spentex® v. NOMEX®
Flash Fire Demonstration

 
Extra | Double Click
Button | More Videos
Extra | You may also be interested in
 

You May Also Be Interested In

Firebane
preFooter-Location
  • Where we are
  • GSL, Inc.
  • 4129 South 72nd East Ave.
  • Tulsa, OK 74145
  • USA
preFooter-Contact-Form
1-877-800-1222